When setting parameters, refer to the instruction manual (applied) and understand instructions.
The inverter can be used to exercise process control, e.g. flow rate,
air volume or pressure.
The terminal 2 input signal or parameter setting is used as a set
point and the terminal 4 input signal used as a feedback value to
constitute a feedback system for PID control.
Pr.128
= "20, 21" (Measured value input)
The display language of the parameter unit (FR-PU07) can be
changed.
When using an FR-E500 series operation panel (PA02), the
frequency setting method can be switched using
Pr.146
Built-in
potentiometer switching
.
The output current during inverter running can be detected and
output to the output terminal.
(1) Output current detection
(Y12 signal,
Pr. 150, Pr. 151, Pr. 166, Pr. 167
)
The output current detection function can be used for
excessive torque detection, etc.
If the output during inverter running is the
Pr.150
setting or
higher for the time set in
Pr.151
or longer, the output
current detection signal (Y12) is output from the inverter's
open collector or relay output terminal.
(2) Zero current detection (Y13 signal,
Pr. 152, Pr. 153
)
If the output during inverter running is the
Pr.152
setting or
lower for the time set in
Pr.153
or longer, the zero current
detection signal (Y13) is output from the inverter's open
collector or relay output terminal.
Parameter which can be read from the operation panel and
parameter unit can be restricted.
In the initial setting, only the simple mode parameters are displayed.
127 to 134, 553, 554, 575 to 577, C42(934) to C45(935)
PID control
Pr.127 PID control automatic switchover frequency
Pr.128 PID action selection
Pr.129 PID proportional band
Pr.130 PID integral time
Pr.131 PID upper limit
Pr.132 PID lower limit
Pr.133 PID action set point
Pr.134 PID differential time
Pr.553 PID deviation limit
Pr.554 PID signal operation selection
Pr.575 Output interruption detection time
Pr.576 Output interruption detection level
Pr.577 Output interruption cancel level
C42(Pr.934) PID display bias coefficient
C43(Pr.934) PID display bias analog value
C44(Pr.935) PID display gain coefficient
C45(Pr.935) PID display gain analog value
145
Parameter unit display language
selection
Pr.145 PU display language selection
Pr.145
setting
Description
0 (initial value)
Japanese
1
English
2
German
3
French
4
Spanish
5
Italian
6
Swedish
7
Finnish
146
Built-in potentiometer switching
Pr.146 Built-in potentiometer switching
Pr.146
setting
Description
0
Built-in frequency setting potentiometer
1 (initial value)
Digital frequency setting with the "UP/DOWN" key
9999
The frequency setting with the built-in frequency
setting potentiometer is enabled when the frequency
setting with the "UP/DOWN" key is "0 Hz".
+-
M
PID operation
Pr. 133
or terminal 2
Set point
Inverter circuit
Motor
Feedback signal (measured value)
Terminal 4
Kp: Proportionality constant Ti: Integral time S: Operator Td: Differential time
Manipulated
variable
0 to 5VDC
(0 to 10VDC)
4 to 20mADC (0 to 5V, 0 to 10V)
Ti
S
Kp 1+ +Td S
1
150 to 153, 166, 167
Detection of output current (Y12 signal)
detection of zero current (Y13 signal)
Pr.150 Output current detection level
Pr.151 Output current detection signal delay time
Pr.152 Zero current detection level
Pr.153 Zero current detection time
Pr.166 Output current detection signal retention time
Pr.167 Output current detection operation selection
Once turned ON, the zero current detection time
signal (Y13) is held on for at least 0.1s.
154, 156, 157
Refer to the section about
Pr.22
160
Extended parameter display
Pr.160 Extended function display selection
Pr.160
setting
Description
0
Displays all parameters
9999
(initial value)
Displays only the simple mode parameters
Time
Pr. 150
OFF
ON
OFF
Output current
detection signal
(Y12)
Pr. 166
Output current
Pr. 166
9999,
Pr. 167
= 0
Pr. 151
OFF
ON
Start signal
Time
Output current
OFF
ON
Zero current
detection time
(Y13)
Pr. 153
Detection time
Pr. 153
Detection time
Pr. 152
OFF
ON
0[A]
0.1s
∗
Pr. 152