82
When
Pr.80 Motor capacity
"9999," the
Pr.80 Motor capacity
setting is not changed by IPM parameter initialization. IPM parameter initialization is performed
by setting
Pr.998 IPM parameter initialization
or the parameter setting mode on the operation panel.
<IPM motor specification list>
893
Energy saving monitor reference
(motor capacity)
Rated inverter capacity
Motor capacity
(Pr.80)
0.01kW
C24(923)
Frequency setting voltage gain
frequency (built-in potentiometer)
60Hz
Rated motor
rotations per minute
Rated motor
frequency
1 r/min
0.01Hz
REMARKS
If IPM parameter initialization is performed in rotations per minute (
Pr. 998
= "1"), the frequency-related parameters not listed in
the table above and the monitored items are also set and displayed in rotations per minute.
The
Pr. 998
setting automatically changes the
Pr. 71
setting but does not change
Pr. 0 Torque boost
and
Pr. 12 DC injection brake
operation voltage
settings.
MM-EF
MM-EFS
Rated motor frequency
(rotations per minute)
90Hz (1800 r/min)
75Hz (1500 r/min)
Maximum motor frequency
(rotations per minute)
135Hz (2700 r/min)
112.5Hz (2250 r/min)
Minimum frequency
(rotations per minute)
9Hz (180 r/min)
7.5Hz (150 r/min)
Specification comparison with the general-purpose motor
Item
IPM motor control
General-purpose motor control
Applicable motor
Premium high-efficiency IPM motor MM-EFS series
(the same capacity as the inverter capacity)
General-purpose motor SF-JR, HR series, etc.
(the same or one-rank higher capacity compared to
the inverter)
Number of connectable
motors
1: 1
Several motors can be driven under V/F control.
Number of motor poles
6 poles
Normally 2, 4, or 6 poles.
Rated motor frequency
75Hz
Normally 50Hz or 60Hz
Maximum output
frequency
112.5Hz (6P 2250r/min)
400Hz (12000r/min with 4P) (Set the upper limit
frequency
(Pr.1, Pr.18)
according to the motor and
machine specifications.)
Permissible load
120% 60s, 150% 0.5s (inverse-time characteristics)
(The % value is a ratio to the rated motor current.)
120% 60s, 150% 0.5s (inverse-time characteristics)
(The % value is a ratio to the rated inverter current.)
Maximum starting
torque
50%
120% (General-purpose magnetic flux vector control)
Frequency
setting
resolution
Analog
input
0.018Hz/0 to 75Hz (1500r/min)
(0 to 10V / 12 bits)
0.036Hz/0 to 75Hz (1500r/min)
(0 to 5V / 11 bits, 0 to 20mA / 11 bits, 0 to
10V /
12 bits)
0.072Hz/0 to 75Hz (1500r/min)
(0 to
5V / 11 bits)
0.015Hz/0 to 60Hz (1800r/min with 4P)
(0 to 10V / 12 bits)
0.03Hz/0 to 60Hz (1800r/min with 4P)
(0 to 5V / 11 bits, 0 to 20mA / 11 bits, 0 to
10V /
12 bits)
0.06Hz/0 to 60Hz (1800r/min with 4P)
(0 to
5V / 11 bits)
Output
signal
Pulse
output for
meter
In the initial setting, 1mA is output at 75Hz from
across terminals FM and SD. (SD is a common
terminal.)
The permissible frequency load current is 2mA.
For pulse specification, 1440 pulses/s is output at
75Hz.
In the initial setting, 1mA is output at 60Hz from
across terminals FM and SD.
(SD is a common terminal.)
The permissible frequency load current is 2mA.
For pulse specification, 1440 pulses/s is output at
60Hz.
Carrier frequency
five patterns of 2.5kHz, 5kHz, 7.5kHz, 10kHz and
12.5kHz
0.75kHz to 14.5kHz
Parameter
Name
Setting
Setting increments
General-purpose
motor
IPM motor
(rotations per
minute)
IPM motor
(frequency)
Pr.998
0
(Initial setting)
1 (MM-EF),
12 (MM-EFS)
101 (MM-EF),
112 (MM-EFS)
1, 12
0, 101, 112
Summary of Contents for F720PJ-11KF
Page 88: ...88 MEMO ...