Harmonic suppression guideline
Inverters have a converter section (rectifier circuit) and generate a
harmonic current.
Harmonic currents flow from the inverter to a power receiving point via
a power transformer. The Harmonic Suppression Guidelines were
established to protect other consumers from these outgoing harmonic
currents.
The three-phase 200V input specifications 3.7kW or less are
previously covered by "Harmonic Suppression Guidelines for
Household Appliances and General-Purpose Products" and other
models are covered by "Harmonic Suppression Guidelines for
Consumers Who Receive High Voltage or Special High Voltage".
However, the transistorized inverter has been excluded from the target
products covered by "Harmonic Suppression Guidelines for Household
Appliances and General-Purpose Products" in January 2004 and
"Harmonic Suppression Guidelines for Household Appliances and
General-Purpose Products" was repealed on September 6, 2004.
All capacity and all models of general-purpose inverter used by specific
consumers are covered by "Harmonic Suppression Guidelines for
Consumers Who Receive High Voltage or Special High Voltage"
(hereinafter referred to as "Specific Consumer Guidelines").
Harmonic Suppression Guideline for Consumers Who Receive High
Voltage or Special High Voltage
This guideline sets forth the maximum values of harmonic currents
outgoing from a high-voltage or especially high-voltage consumer who
will install, add or renew harmonic generating equipment. If any of the
maximum values is exceeded, this guideline requires that consumer to
take certain suppression measures.
Users who use models other than the target models are not covered by
the guideline. However, we ask to connect an AC reactor and a DC
reactor as before.
For compliance to the "Harmonic Suppression Guideline for
Consumers Who Receive High Voltage or Special High Voltage"
For compliance to "Harmonic suppression guideline of the general-
purpose inverter (input current of 20A or less) for consumers other than
specific consumers" published by JEMA
Calculation of outgoing harmonic current
Input
Power
Supply
Target
Capacity
Measures
Three-
phase
200V
Three-
phase
400V
All
capacities
Make a judgment based on the "Harmonic
Suppression Guideline for Consumers Who
Receive High Voltage or Special High Voltage"
issued by the Japanese Ministry of Economy,
Trade and Industry (formerly Ministry of
International Trade and Industry) in
September 1994 and take measures if
necessary. For calculation method of power
supply harmonics, refer to materials below.
Reference materials
"Harmonic suppression measures of the
general-purpose inverter"
Jan., 2004 Japan Electrical Manufacturer's
Association
"Calculation method of harmonic current of
the general-purpose inverter used by
specific consumers"
JEM-TR201 (Revised in December 2003) :
Japan Electrical Manufacturer's Association
Input
Power
Supply
Target
Capacity
Measures
Three-
phase
200V
3.7kW
or less
Connect the AC reactor or DC reactor
recommended in a catalog or an instruction
manual.
Reference materials
"Harmonic suppression guideline of the
general-purpose inverter (input current of
20A or less)"
JEM-TR226 (Revised in December 2003) :
Japan Electrical Manufacturer's Association
Outgoing harmonic current = fundamental wave current (value converted
from received power voltage)
operation ratio
harmonic content
Operation ratio: Operation ratio = actual load factor
operation time
ratio during 30 minutes
Harmonic content: Found in Table.
Table 1: Harmonic content (Values of the fundamental current is 100%)
Reactor
5th 7th 11th 13th 17th 19th 23th 25th
Three-phase
bridge
(Capacitor
smoothing)
Not used
65
41
8.5
7.7
4.3
3.1
2.6
1.8
Used (AC side)
38 14.5
7.4
3.4
3.2
1.9
1.7
1.3
Used (DC side)
or with
Filterpack
30
13
8.4
5.0
4.7
3.2
3.0
2.2
Used (AC, DC
sides)
28
9.1
7.2
4.1
3.2
2.4
1.6
1.4
Table 2: Rated capacities and outgoing harmonic currents
of inverter-driven motors
Applied
Motor
kW
Fundamental
Wave Current
(A)
Fundamental
Wave Current
Converted
from 6.6kV
(mA)
Rated
Capacity
(kVA)
Fundamental Wave Current
Converted from 6.6kV
(No reactor, 100% operation ratio)
200V 400V
5th 7th 11th 13th 17th 19th 23th 25th
0.4
1.61
0.81
49
0.57
31.85 20.09 4.165 3.773 2.107 1.519 1.274 0.882
0.75
2.74
1.37
83
0.97
53.95 34.03 7.055 6.391 3.569 2.573 2.158 1.494
1.5
5.50
2.75
167
1.95
108.6 68.47 14.20 12.86 7.181 5.177 4.342 3.006
2.2
7.93
3.96
240
2.81
156.0 98.40 20.40 18.48 10.32 7.440 6.240 4.320
3.7
13.0
6.50
394
4.61
257.1 161.5 33.49 30.34 16.94 12.21 10.24 7.092
5.5
19.1
9.55
579
6.77
376.1 237.4 49.22 44.58 24.90 17.95 15.05 10.42
7.5
25.6
12.8
776
9.07
504.4 318.2 65.96 59.75 33.37 24.06 20.18 13.97
11
36.9
18.5
1121
13.1
728.7 459.6 95.29 86.32 48.20 34.75 29.15 20.18
15
49.8
24.9
1509
17.6
980.9 618.7 128.3 116.2 64.89 46.78 39.24 27.16
Table 3: Conversion factors
Classification
Circuit type
Conversion
coefficient Ki
3
Three-phase bridge
(Capacitor smoothing)
Without reactor
K31 = 3.4
With reactor (AC side)
K32 = 1.8
With reactor (DC side)
K33 = 1.8
With reactors (AC, DC sides)
K34 = 1.4
5
Self-excitation
three-phase bridge
When a high power factor
converter is used
K5 = 0