When setting parameters, refer to the instruction manual (applied) and understand instructions.
You can change the functions of the open collector output terminal
and relay output terminal.
This function is available only under IPM motor control.
You can control the operation of the cooling fan (1.5K or higher)
built in the inverter.
The inverter output current may be used to assume motor slip to
keep the motor speed constant.
This function is also enabled under V/F control.
You can choose whether to make earth (ground) fault detection at
start valid or invalid. Earth (Ground) fault detection is executed
only right after the start signal is input to the inverter.
As detection is executed at start, output is delayed for approx. 20ms every
start.
If an earth (ground) fault is detected with "1" set in
Pr. 249
, output
side earth (ground) fault overcurrent (E.GF) is detected and the
inverter trips.
Protective function will not activate if an earth (ground) fault occurs
during operation.
If the motor capacity is smaller than the inverter capacity when using
the 5.5K or higher, earth (ground) fault detection may not be
provided.
190, 192
Terminal assignment of output terminal
Pr.190 RUN terminal function selection
Pr.192 A,B,C terminal function selection
Pr.190, Pr.192
setting
Signal
Name
Function
Positive
logic
Negative
logic
0
100
RUN
Inverter running
1
101
SU
Up to frequency
3
103
OL
Overload alarm
4
104
FU
Output frequency detection
7
107
RBP
Regenerative brake prealarm
8
108
THP
Electronic thermal relay function
prealarm
11
111
RY
Inverter operation ready
12
112
Y12
Output current detection
13
113
Y13
Zero current detection
14
114
FDN
PID lower limit
15
115
FUP
PID upper limit
16
116
RL
PID forward/reverse rotation
output
25
125
FAN
Fan fault output
26
126
FIN
Heatsink overheat pre-alarm
46
146
Y46
During deceleration at
occurrence of power failure
(retained until release)
47
147
PID
During PID control activated
48
148
Y48
PID deviation limit
57
157
IPM
IPM motor control
64
164
Y64
During retry
70
170
SLEEP
During PID output suspension
79
179
Y79
Pulse train output of output power
90
190
Y90
Life alarm
91
191
Y91
Alarm output 3 (power-off signal)
92
192
Y92
Energy saving average value
updated timing
93
193
Y93
Current average monitor signal
95
195
Y95
Maintenance timer signal
96
196
REM
Remote output
98
198
LF
Minor fault output
99
199
ALM
Alarm output
9999
No function
232 to 239
Refer to the section about
Pr.4
240
Refer to the section about
Pr.72
241
Refer to the section about
Pr.125
244
Increase cooling fan life
Pr.244 Cooling fan operation selection
Pr.244
setting
Description
0
The cooling fan operates at power on.
Cooling fan on/off control invalid (The cooling
fan is always on at power on)
1
(initial value)
Cooling fan on/off control valid.
The fan is normally on during inverter
operation. The fan switches on/off according to
the temperature during a stop of the inverter
whose status is monitored.
245 to 247
Slip compensation
Pr.245 Rated slip
Pr.246 Slip compensation time constant
Pr.247 Constant-power range slip compensation selection
249
Earth (ground) fault detection at start
Pr.249 Earth (ground) fault detection at start
Pr.249
setting
Description
0
(initial value)
Without earth (ground) fault detection
1
With earth (ground) fault detection
V/F
V/F
V/F
GP
MFVC
GP
MFVC
GP
MFVC