Optional Parts
Notes:
*1.Under Normal heating conditions at the outdoor temp,
16°CDB/12°CWB(60.8°FDB/53.6°FWB), the outlet water
temperature 65°C(149°F), and the inlet water temperature
17°C(62.6°F)
*2.Under Normal heating conditions at the outdoor temp,
7°CDB/6°CWB(44.6°FDB/42.8°FWB), the outlet water tempera-
ture 65°C(149°F), and the inlet water temperature 9°C(48.2°F)
*3.Under Normal heating conditions at the outdoor temp,
7°CDB/6°CWB(44.6°FDB/42.8°FWB), the outlet water tempera-
ture 65°C(149°F), and the inlet water temperature 15°C(59.0°F)
*4.Under Normal heating conditions at the outdoor temp,
7°CDB/6°CWB(44.6°FDB/42.8°FWB), when the unit is set to the
“Capacity Priority“ mode through the dry NC-contact.
*Due to continuing improvements, specifications may be sub-
ject to change without notice
*Do not use steel pipes as water pipes.
*Keep the water circulated at all times. Blow the water out of
the pipes if the unit will not be used for an extended period
time.
*Do not use ground water or well water
*Do not install the unit in an environment where the wet bulb
temperature exceeds 32°C
*The water circuit must use the closed circuit
*There is a possibility that the unit may abnormally stop when
it operates outside its operating range. Provide backup (ex.
boiler start with error display output signal (blue CN511 1-3))
for abnormal stop.
UNIT CONVERTER
BTU/h = kW x 3,412
lbs
= kg/0.4536
QAHV-N560YA-HPB
Power Source
3-phase 4-wire 380-400-415V 50Hz
Capacity *1
kW
40
Btu/h
136480
Power Input
kW
10.31
Current Input
A
17.8-16.9-16.3
COP(kW/kW)
3.88
Capacity *2
kW
40
Btu/h
136480
Power Input
kW
10.97
Current Input
A
20.0-19.0-18.3
COP(kW/kW)
3.65
Capacity *3
kW
40
Btu/h
136480
Power Input
kW
11.6
Current Input
A
20.4-19.4-18.7
COP(kW/kW)
3.44
Maximum Current Input *4
A
28.8-27.4-26.4
Allowable External Pump Head
77kPa
Temperature Range
Outlet Water Temp
55–90°C
Outdoor Temp
D.B.
-25~43°C
Sound Pressure Level (measured 1m below the unit
in an anechoic room) *1
dB(A)
56
Water Pipe
Diameter and Type
Inlet
mm(in.)
19.05(Rc 3/4"), screw pipe
Outlet
mm(in.)
19.05(Rc 3/4"), screw pipe
External Finish
Acrylic painted steel plate
<MUNSELL 5Y 8/1 or similar>
External Dimension H x W x D
mm
1837(1777 not including legs) x 1220 x 760
Net Weight
kg(lbs)
400(882)
Design Pressure
R744
MPa
14
Water
MPa
1.0
Heat Exchanger
Water-side
Copper tube coil
Air-side
Plate fin and copper tube
Compressor
Type
Inverter scroll hermetic compressor
Maker
MITSUBISHI ELECTRIC CORPORATION
Motor Output
kW
11.0
Case Heater
kW
0.045
FAN
Air Flow Rate
m3/min
220
L/s
3666
Type x Quantity
Propeller fan
Control, Driving Mechanism
Inverter-control, Direct-driven by motor
Motor Output
kW
0.92
HIC (HIC: Heat inter-changer) Circuit
Copper pipe
Protection
High Pressure Protection
High pres.Sensor & High pres.
Switch at 14MPa(643psi)
Inverter Circuit
Overheat and overcurrent protection
Compressor
Overheat protection
Fan Motor
Thermal switch
Defrosting Method
Auto-defrost mode (Hot gas)
Refrigerant
Type x Original Charge
CO
2
(R744) 6.5kg
Remote
Controller
PAR-W31MAA-J
Representative Water
Temperature Sensor
TW-TH16-E
228
HOT WATER HEAT PUMPS
Summary of Contents for City Multi R2 Series
Page 1: ...CM20AN E NZ VRF City Multi Product Catalogue ...
Page 101: ...BC Controllers 101 ...
Page 112: ...Indoor Units VRF 112 ...
Page 114: ...Ceiling Cassette Type 4 Way Airflow Type 114 ...
Page 122: ...Ceiling Cassette Type 2 Way Airflow Type 122 ...
Page 128: ...Ceiling Concealed Type 128 ...
Page 150: ...Wall Mounted Type 150 ...
Page 154: ...Floor Standing Type 154 ...
Page 181: ...Ventilation Systems 181 ...
Page 190: ...Remote Controllers 190 ...