• Dual set point
When the operation mode is set to Auto (dual set point)
mode, two preset temperatures (one each for cooling and
heating) can be set. Depending on the room temperature, the
indoor unit will automatically operate in either the Cool or
Heat mode and keep the room temperature within the preset
range.
*Contact your Mitsubishi Electric sales office for details.
• Backlit LCD
Backlight for operation in dark places
• Flat back
The remote controller can be installed without making a hole
in the wall.
Thickness is less than 14.5 mm (19/32 in).
• Vane button (standard)
The Vane button has been added to allow users to change
airflow direction (ceiling cassette and wall mounted types).
Pressing the button changes the vane direction.
*The vane directions that can be set varies depending on the indoor unit
model.
* If the unit has no vane function, vane direction cannot be set.
In this case, the vane icon blinks when the button is pressed.
• Only cross-over wiring is required, based on two-wire
signal lines.
• Room temperature sensors are built in.
• Compatible with all types of indoor units
*As this controller has limited functions, it should always be used in
conjunction with a standard controller or centralized controller.
• LCD temperature setting and display in 1°C/1°F incre-
ments
Dimensions: 70(W) x 120(H) x 14.5(D) mm
: 2-3/4(W) x 4-3/4(H) x 19/32(D) in.
Item
Operation mode switching
Temperature setting
ON/OFF
Fan speed setting
Select from COOL, DRY, FAN, AUTO, and HEAT.
* AUTO mode is settable only when those functions are available on the indoor unit.
Ventilation equipment
When the CITY MULTI indoor unit is connected, interlocked setting of the CITY MULTI Lossnay unit is possible.
When the Mr. SLIM indoor unit (A-control) is connected, interlocked operation of the LGH-R(V)X Type Lossnay unit is possible.
Changes the set temperature.
* Set temperature range varies depending on the indoor unit model.
Changes the fan speed.
* The settable fan speed varies depending on the indoor unit model to be connected.
Permit / Prohibit local operation
By setting a centralized controller, the following local operations can be prohibited: ON/OFF, operation mode,
preset temperature;
* The CENTRAL icon appears while local operations are prohibited.
Description
Operations
: Each unit : Each group : Not available
Display
Changes between ON and OFF.
Error
Displays the current error status with the address.
* The address may not be displayed depending on the error status.
Set temperature range limit
The preset temperature range can be restricted for each operation mode (COOL/HEAT/AUTO).
X
X
AUTO
Setting 1
Setting 2
Setting 3
Setting 4
Setting 5
Swing
Dual
Set
Point
Dual
Set
Point
Simple
MA R/C
Simple
MA R/C
Centralized controller
AE-200E
• Functions
PAC-YT52CRA (MA)
R/C: Remote controller
• System configuration example
Simple Remote Controller
PAR-FL32MA
PAR-FA32MA
Dimensions: 58(W) x 159(H) x 19(D) mm
: 2-5/16(W) x 6-5/16(H) x 3/4(D) in.
Dimensions: 70(W) x 120(H) x 22.5(D) mm
: 2-3/4(W) x 4-3/4(H) x 7/8(D) in.
PAR-SL94B-E
(Wireless remote controller kit for ceiling suspended type)
Dimensions: 182(W) x 57(H) x 31(D) mm
PAR-SF9FA-E
(2 x 2 cassette signal receiver)
Dimensions: 214(H) x 25.5(D) mm
Some models will have a different display for the air flow direction and fan speed. Set the air flow direction and fan speed when performing initial settings.
: Each group : Not available
Item
ON/OFF
Temperature setting
Air flow direction setting
Ventilation equipment
Timer operation
ON and OFF operation for a single group
Changes the set temperature.
* Set temperature range varies depending on the indoor unit model.
Up to 16 indoor units can be connected to an interlocked system that has one Lossnay.
The Lossnay will run in interlock with the operation of the indoor unit. *2 The fan rate and mode cannot be changed.
Permit / Prohibit local operation
Individually prohibit operation of each local remote control function (ON/OFF, Change operation mode, Set
temperature, Reset filter).
*1 If operation is performed when the local remote controller inactivation command is received from the main system
controller, a buzzer will sound and an LED will flash.
Description
Operations Display
One ON/OFF setting can be set per day.
Air flow direction angles (4-angle, Swing) Auto Louver ON/OFF.
Air flow direction settings vary depending on the model.
X
X
X
*1
*2
PAR-SL100A-E
(PLFY-P/WL VEM, PLFY-P/WL VFM, PKFY-P/WL VLM/VKM only)
Dimensions: 66(W) x 188(H) x 22(D) mm
: 2-5/8(W) x 7-13/32(H) x 7/8(D) in.
Compatibility table (VRF)
PMFY-P*VBM
PLFY-P*VLMD
PEFY-P*VMR-E/VMH(S)
PFFY-P*VLEM/VKM/VLRM/VLRMM
PEFY-P*VMS1(L)
PEFY-P*VMA(3)(L)
PAR-FL32MA
Receiver
Transmitter
PAR-FA32MA
PCFY-P*VKM
PKFY-P*VKM
PKFY-P*VLM
PLFY-P*VEM
PLFY-P*VFM-E1
PAR-FL32MA
PAR-SL100A-E
Receiver
Transmitter
PAR-FA32MA
PAR-SL94B-E
PAR-SE9FA-E
PAR-SF9FA-E
Built-in
Built-in
• Functions
PAR-SE9FA-E
(4-way cassette signal receiver)
Dimensions: 273(H) x 29(D) mm
Signal
receiving
unit
Non-polarized
2-wire
Wireless
remote
controller
PAR-FA32MA
PAR-SL94B-E
Signal
receiving
unit
PAR-SL94B-E
Wireless
remote
controller
Signal
receiving
unit N/A
Indoor unit
grouping
N/A
Wireless
remote
controller
PAR-SL100A-E
PAR-SF9FA-E
PAR-SE9FA-E
• No need to configure addresses for group operation.
• The LED remains lit to show operation status. It also provides error information via the number of blinks.
• Can be used with the MA remote controller
.
*When used in group configurations, wiring is required between indoor units.
*ME remote controller and/or Lossnay remote controller cannot be combined in the same group.
• Multiple indoor units cannot be controlled with the PAR-SL100A-E.
Only one indoor unit can be used in each group.
• LCD temperature setting and display in 1°C/1°F increments.
• System configuration example
Wireless Remote Controller
PEFY-WP*VMS1
PEFY-W*VMS
PEFY-WP*VMA
PEFY-W*VMA(L)(2)
PFFY-WP*VLRMM
PFFY-W*VCM
PLFY-WL*VEM
PLFY-WL*VFM
PKFY-WL*VLM/VKM
PAR-FL32MA
PAR-SL100A-E
PAR-FA32MA
PAR-SE9FA-E
PAR-SF9FA-E
Built-in
Receiver
Transmitter
Compatibility table (HVRF)
199
VRF
Y-Series
VRF
Lineup
VRF
R2-Series
VRF
Zubadan
VRF
WY-Series
VRF
WR2-Series
VRF
S-Series
VRF
Indoor Units
Ventilation
Systems
Technologies and Functions
Remote Controller
Hot Water Solution
VRF
BC Controllers
VRF
S-Series
INDIVIDUAL REMOTE CONTROLLER
Summary of Contents for City Multi R2 Series
Page 1: ...CM20AN E NZ VRF City Multi Product Catalogue ...
Page 101: ...BC Controllers 101 ...
Page 112: ...Indoor Units VRF 112 ...
Page 114: ...Ceiling Cassette Type 4 Way Airflow Type 114 ...
Page 122: ...Ceiling Cassette Type 2 Way Airflow Type 122 ...
Page 128: ...Ceiling Concealed Type 128 ...
Page 150: ...Wall Mounted Type 150 ...
Page 154: ...Floor Standing Type 154 ...
Page 181: ...Ventilation Systems 181 ...
Page 190: ...Remote Controllers 190 ...