: Standard
: Optional −: Not available
Type
Ceiling cassette type
Ceiling concealed type
4-way airfl ow type
2-way
airfl ow type
1-way
airfl ow type
Low noise
type
Compact
depth type
Low static
pressure type
Medium static
pressure type
Model
PLFY-P
VEM-E/A
PLFY
EM
PLFY-P
VFM-E1
PLFY
FM
PLFY-P
VLMD-E
PLFY
LMD
PMFY-P
VBM-E
PMFY
BM
PEFY-P
VMR-E-L/R
PEFY
MR
PEFY-P
VMX(L)-E(1)
PEFY
MX
PEFY-P
VMS1(L)-E
PEFY
MS
PEFY-P
VMA(L)
PEFY
MA
►
i-see Sensor
3D i-see Sensor
*1
*1
−
−
−
−
−
−
►
Air distribution
Automatic air-speed
adjustment
*2
−
−
−
Fan speed setting
4 levels
3 levels
P20−P100: 3 levels
P125: 4 levels
4 levels
3 levels
3 levels
3 levels
3 levels
Vane setting
*4
5 levels
+Auto
5 levels
+Auto
4 levels
(Auto: N/A)
4 levels
+Auto
−
−
−
−
Swing
−
−
−
−
►
Convenience
Dry operation
Dual set point
*5
External static
pressure setting
−
−
−
−
1 level
P15−P40: 3 levels
P50, P63: 4 levels
4 levels
5 levels
Automatic restoration
after power failure
High effi ciency
fi lter
−
−
−
−
−
−
−
►
Installability and serviceability
Drain pump
−
VMX:
VMXL: −
VMS1:
VMS1L:
VMA:
VMAL: −
Pump head (mm)
*6
850
850
P20−P100: 583
P125: 600
600
−
350
550
700
Filter cleaning
sign
*8
*1 Requires a panel with the 3D i-see Sensor (sold separately). An MA remote controller (PAR-40MAA) is required to set the 3D i-see Sensor. Some settings can be made using the
PAR-SL100A-E.
*2 To set the fan speed to Auto using the wireless remote controller, certain controller settings need to be made beforehand. Refer to the installation manual of the wireless remote
controller for details on how to make the settings.
*3
The airfl ow rate mode can be set to either Normal or High. Three fan speeds are available in each mode. Select the mode with the DipSW on the indoor unit. Contact your local
distributor for details.
*4 The available vane angle positions will depend on the remote controller to be used. Refer to the instruction manual of the relevant remote controller for details.
*5 Should be supported by indoor unit and remote controller.
*6 Pump head from the bottom of the unit
*7 Pump head from the top of the unit
*8 Factory setting: OFF
VRF
Y-Series
VRF
Lineup
VRF
R2-Series
VRF
Zubadan
VRF
WY-Series
VRF
WR2-Series
VRF
S-Series
VRF
Indoor Units
Ventilation
Systems
Technologies and Functions
Remote Controller
Hot Water Solution
VRF
BC Controllers
VRF
S-Series
167
VRF INDOOR UNIT FUNCTION TABLE
Summary of Contents for City Multi R2 Series
Page 1: ...CM20AN E NZ VRF City Multi Product Catalogue ...
Page 101: ...BC Controllers 101 ...
Page 112: ...Indoor Units VRF 112 ...
Page 114: ...Ceiling Cassette Type 4 Way Airflow Type 114 ...
Page 122: ...Ceiling Cassette Type 2 Way Airflow Type 122 ...
Page 128: ...Ceiling Concealed Type 128 ...
Page 150: ...Wall Mounted Type 150 ...
Page 154: ...Floor Standing Type 154 ...
Page 181: ...Ventilation Systems 181 ...
Page 190: ...Remote Controllers 190 ...