63
Torque Current Output
Current Output Specifications (Models: OPT-564-T2/OPT-564-T3)
Specifications
Details
Output
4 mA to 20 mA DC
Non-linearity
Within 0.05 % R.O.
Resolution
Approx. 1/12,000 or more
Over-range
Approx. 2.4 mA DC for [-OL] indication
Approx. 21.6 mA DC for [OL] indication
Output cycles
Approx. 10,000 cycles/s
Group delay time
Filter setting
Group delay time
(typ.)
6 kHz
0.27 ms
1 kHz
0.56 ms
500 Hz
0.99 ms
300 Hz
1.7 ms
100 Hz
5.8 ms
50 Hz
11 ms
30 Hz
14 ms
10 Hz
50 ms
1 Hz
328 ms
Current Output Settings
The following current output settings can be selected for this equipment at the time of purchase.
Model
At negative rated
torque
At zero torque
At positive rated
torque
OPT-564-T2
–
4 mA
20 mA
OPT-564-T3
4 mA
12 mA
20 mA
Current Output Electrical Conditions
Load resistance
510 Ω or less