1
Part Names and Functions
Front Panel
Torque units display
Displays the measurement units set.
Torque display
Displays the torque reading and "OL" (for over limit).
Status display
Indicates the OPT-564 status.
H:
Illuminates when the torque meter light level is normal.
M:
Illuminates when the torque meter light level is low.
Note that "M" does not illuminate if used in conjunction with the DBX-001 power supply box.
A/Z:
Illuminates when the A/Z function operates.
CHECK: Illuminates when the
key is pressed to turn CHECK on.
LOCK:
Illuminates when external control input LOCK to COM is short-circuited.
ERROR: Illuminates when an error signal is output.
Rotation speed units display
Displays the rotation speed units.
Rotation speed display
Displays the rotation speed and "OS" (for overspeed).
(4) Rotation speed units
display
(2) Torque
display
(1) Torque units display
(3) Status display
(5) Rotation
speed
display
(6) to (13)
Key switches
(14) Calibration number
display