![MIMAKI ME-300STII Operation Manual Download Page 74](http://html1.mh-extra.com/html/mimaki/me-300stii/me-300stii_operation-manual_1800196074.webp)
5-6
Troubleshooting
If the following troubles have occurred, check each check point.
Power is not turned on.
The cutter is not lowered.
The spindle does not rotate.
Trou-
ble
The power lamp on the operation panel does not light if the power switch is on.
Check Point
Solution
1. Is the power cable connected firmly?
Connect it to the machine and to the receptacle
firmly.
P.1-7
2. Is the cable of the operation panel connected to
the machine firmly?
Connect it to the machine firmly.
P.1-7
3. Is the emergency stop switch released?
Release the emergency stop switch.
P.2-5
Trou-
ble
The machine is running with the cutter raised.
Check Point
Solution
1. Is Z axis reference point set?
Set Z axis reference point.
P.3-8
2. Is the vacuum hose pulling up the chip removal
attachment?
Mount it in order not the vacuum hose to pull up.
P.1-12
Trou-
ble
The machine is running with the spindle stopped.
Check Point
Solution
1. Is the spindle rotated before sending data from
the host computer?
Set the spindle rotation to ON before sending
data.
P.2-7
2. Did the host computer send a command to stop
rotation of the spindle?
Release the command following the operation
manual of the host computer.
3. Is the SPINDLE of the operation switch OFF?
Set the SPINDLE of the operation switch to OFF.
P.4-7
Summary of Contents for ME-300STII
Page 12: ...12 Machine Specification 6 10 Interface Specification 6 11 Supported G code List 6 12...
Page 26: ...2 2 Operation Panel The names and functions of the operation panel components are as follows...
Page 68: ...4 14...
Page 69: ...5 1 CHAPTER 5 ERRORS AND SOLUTIONS...
Page 76: ...5 8...
Page 77: ...6 1 CHAPTER 6 APPENDIX...
Page 89: ......