How to Set Communication Conditions
4-9
How to Set Communication Conditions
Specify the communication conditions for RS-232C interface.
“*” indicates the default value.
1
Press
(or
) to display
the third page of the local mode.
2
Press
(or
) to display
the screen shown on the right.
3
Press
(or
) to select
RS-232C.
Press the function key to set the values of BAUD
RATE, DATA BITS, and PARITY.
4
Press
to go to the next page.
Press the function key to set the values of STOP BITS
and HANDSHAKE.
To return to the previous page, press
.
5
Press
to fix the setting.
*1
Item
Indications on LCD
Description
Baud Rate
1200
1200 bps
2400
2400 bps
4800
4800 bps
9600*
9600 bps
19200
19200 bps
Data Bits
7
7 bits
8*
8 bits
Parity
NON*
Parity check is not performed.
EVEN
Even parity
ODD
Odd parity
Stop Bits
1*
1 bit
1.5
1.5 bits
2
2 bits
Handshake
HARD*
Hardware handshake
CODE
XON/XOFF handshake
*1. Press
on the step 4 to cancel the setting.
[ L C L ] S p i n - O F F 3 / 4
M o d e
S w i t c h
- - >
S e l f
T e s t
- - >
I n t e r f a c e
- - >
F 3
< I n t e r f a c e >
R S - 2 3 2 C
- - >
F 1
< R S - 2 3 2 C >
1 / 2
B a u d
R a t e
* 9 6 0 0 >
D a t a
B i t s
* 8 >
P a r i t y
* E V E N >
F 1
F 2
F 3
< R S - 2 3 2 C >
2 / 2
S t o p
B i t s
* 1 >
H a n d s h a k e
* H A R D >
F 1
F 2
Summary of Contents for ME-300STII
Page 12: ...12 Machine Specification 6 10 Interface Specification 6 11 Supported G code List 6 12...
Page 26: ...2 2 Operation Panel The names and functions of the operation panel components are as follows...
Page 68: ...4 14...
Page 69: ...5 1 CHAPTER 5 ERRORS AND SOLUTIONS...
Page 76: ...5 8...
Page 77: ...6 1 CHAPTER 6 APPENDIX...
Page 89: ......