The “Load level” function will not be enabled unless the following
criteria have been met:
–
The “Load level” function on the corresponding customer card
must be selected and confirmed with “YES”
“Transponder system” on page 98.
–
The “Load level” function must be selected in the device set-
tings and confirmed with “YES” .
The “Load level” function will remain disabled until both of these
criteria are have been met. The function will also remain disabled if
only one of the confirmations has been selected.
Personnel:
n
Trainer
Materials:
n
Transponder card
1.
Place the new transponder card (Fig. 59) in the main menu
on the designated contact surface.
2.
If the transponder card is still unformatted, you will be
prompted to format the transponder card. Confirm the prompt
by selecting
“YES”
using the multi-function button.
3.
If the transponder card is empty, the following question will
be displayed:
“Empty card. Create customer card?”
. Confirm
the prompt by selecting
“YES”
using the multi-function
button.
ð
The system will automatically switch to the
“Card
management”
menu.
4.
Use the multi-function button to set the different default
parameters in the
“Card management”
menu and save them
to the transponder card using the
“Write card”
function.
ð
The transponder card will now be formatted with the
values you have defined and is ready for use.
First use of the transponder card
Fig. 59: Transponder card
Overview of programs/training plans
2021-07-28
miha-bodytec m.ove EMS training device
99