![Midea MVUR252B-VA3 Service Manual Download Page 27](http://html1.mh-extra.com/html/midea/mvur252b-va3/mvur252b-va3_service-manual_1791261027.webp)
MIV V5 Heat Recovery DC Inverter R410A
DM14-01.01.18en
Specifications & Performances
25
1. Specifications
1.1 Outdoor unit specifications
Independent unit specifications
Model
MVUR252B-VA3
MVUR280B-VA3
MVUR335B-VA3
Power supply
V/Ph/Hz
380-415/3/50
380-415/3/60
380-415/3/50
380-415/3/60
380-415/3/50
380-415/3/60
Cooling
Capacity
kW
25.2
28.0
33.5
Btu/h 86,000
95,500
114,300
Power input
kW
5.73
6.67
8.07
EER
kW/kW
4.40
4.20
4.15
Heating
Capacity
kW 27.0
31.5
37.5
Btu/h 92,100
107,500
128,000
Power input
kW
6.00
7.33
8.72
COP
kW/kW
4.50
4.30
4.30
DC inverter
compressor
Model
E655DHD-65D2YG
E655DHD-65D2YG
E655DHD-65D2YG
Type
DC inverter
DC inverter
DC inverter
Brand
Hitachi
Hitachi
Hitachi
Quantity 1
1
1
Capacity
kW 31.59
31.59
31.59
Btu/h 107,800
107,800
107,800
Crankcase heater
W
30×2
30×2
30×2
Refrigerant oil type
FVC68D
FVC68D
FVC68D
Refrigerant oil charge
ml
500
500
500
Outdoor fan
motor
Model
WZDK750-38G-4
WZDK750-38G-4
WZDK750-38G-4
Type
DC motor
DC motor
DC motor
Quantity 2
2
2
Brand
Panasonic/Nidec
Panasonic/Nidec Panasonic/Nidec
Insulation class
E
E
E
Safe class
IP23
IP23
IP23
Input
W
520
520
520
Output W
420
420
420
Outdoor fan
Material Plastic
Plastic Plastic
Type Axial
Axial
Axial
Quantity 2
2
2
External static pressure
Pa 0~20
(default)
Pa
20~60 (need to customize)
Outdoor coil
Number of rows
2
2
2
Tube pitch(a)×row pitch(b)
in.(mm)
7/8×3/4(22×19) 7/8×3/4(22×19) 7/8×3/4(22×19)
Fin spacing
in.(mm)
1/16(1.6)
1/16(1.6)
1/16(1.6)
Fin type
Hydrophilic aluminium
Hydrophilic aluminium
Hydrophilic aluminium
Tube outside diameter
in.(mm)
Ф
5/16(7.94)
Ф
5/16(7.94)
Ф
5/16(7.94)
Tube type
inner-groove tube
inner-groove tube
inner-groove tube
Coil dimension
(W×D×H)
in.(mm)
42×1-1/2×48-1/2
(1067×38×1232)
42×1-1/2×48-1/2
(1067×38×1232)
42×1-1/2×48-1/2
(1067×38×1232)
Condenser quantity
2
2
2