24
3.1.2
24V Charging
24V charging is suitable for diesel vehicles. The operation process is the same as that of 12V charging. The reference
voltage is 26.5V~30V. It can be tested with an oscilloscope. The specific operation is shown in Figure 3-3:
Figure 3-3 24V Charging
3.1.3
Alternator AC Ripple
The ATO oscilloscope can test the charging ripple and assist the user to determine whether the charging process is
normal. Use a BNC to banana cable, one end is connected to the oscilloscope channel 1, and the other end is clamped
between the positive and negative electrodes of the battery (the red wire is connected to the red clip) Connect the
positive pole, and connect the black wire to the black clip to the negative pole). Start the vehicle and start the test.
At this time, the oscilloscope is coupled to AC, and what is displayed is not the true voltage value. It is based on the
DC waveform and the difference relative to the DC voltage.
As shown in Figure 3-4 below: