![Micsig ATO1000 Series User Manual Download Page 111](http://html.mh-extra.com/html/micsig/ato1000-series/ato1000-series_user-manual_1789851111.webp)
108
Figure 6-18 Trigger Time T≠80ns
The trigger pulse width time can be set as 8ns~10s.
Tap the pulse width time setting box
to pop up the time adjustment interface (as shown in Figure
6-19), and adjust the pulse width time. Adjust the pulse width time by adjusting or dragging the time scale.
Figure 6-19 Pulse Width Time Adjustment Interface
6.4 Logic Trigger
Trigger happens when the level between analog channels satisfies a certain logical operation (AND, OR, NAND,
NOR) and the signal voltage reaches the set trigger level and the trigger logic width (8ns~10s). Logic trigger menu
descriptions are shown in the table below:
Trigger
Option
Setting
Description
Trigger
Source
CH1
High
Set CH1 as high
Low
Set CH1 as low
None
Set CH1 as none
CH2
High
Set CH2 as high
Low
Set CH2 as low
None
Set CH2 as none
CH3
High
Set CH3 as high
Low
Set CH3 as low
None
Set CH3 as none
CH4
High
Set CH4 as high
Low
Set CH4 as low
None
Set CH4 as none
Trigger
Summary of Contents for ATO1000 Series
Page 1: ......
Page 2: ...Version Info Version Date Remarks V1 0 2020 06 ...
Page 52: ...Chapter 3 Automotive Test 49 Figure 3 30 Electronic fuel pump test ...
Page 71: ...68 Figure 3 49 K line test ...
Page 79: ...76 Figure 3 57 Mazda 6 Cylinder internal pressure measurement ...