110
Switch the trigger level channel: Tap the trigger level value shown in the upper right corner.
Logic conditions
1)
True: Trigger when the logic changes to true value
2)
False: Trigger when the logic changes to false value
Figure 6-21 Logic Trigger
Trigger pulse width time can be set as 8ns~10s.
Tap the time setting box (
) to pop up the time adjustment interface and adjust the logic time. Please
refer to the Pulse Width Adjustment section for details.
6.5 Nth Edge Trigger
When the trigger signal is triggered on the Nth edge after the specified idle time, it is Nth edge trigger. Menu
descriptions of the Nth edge trigger are shown in the table below:
Trigger
Option
Setting
Description
Trigger
Source
CH1
Set CH1 as trigger signal source
CH2
Set CH2 as trigger signal source
CH3
Set CH3 as trigger signal source
CH4
Set CH4 as trigger signal source
Time
8ns~10s
Idle time
Edge
Rising edge
Set signal trigger on the rising edge