KE300A Inverter MODBUS Communication Protocol
180
Parameter Address
Parameter Description
1010
PID setting
1011
PID feedback
1012
PLC running process
1013
HDI input pulse frequency, unit is 0.01kHz
1014
Feedback speed, unit is 0.1Hz
1015
Remain running time
1016
AI1 voltage before calibration
1017
AI2 voltage before calibration
1018
Reserved
1019
Linear speed
101A
Current power on time
101B
Current running time
101C
HDI input pulse frequency, unit is 1Hz
101D
Communication setting value
101E
Actual feedback speed
101F
Main frequency A display
1020
Auxiliary frequency B display
Note:
Communication setting value is the percentage of relative value, and 10,000 corresponds to 100.00%,
-10000 corresponds to -100.00%.
To the data of frequency, the percentage is the percentage of relative maximum frequency (P0-10).
To the data of torque, the percentage is P2-10 (torque upper limit).
(3) Control command input to inverter (write only)
Command Word Address
Command Function
2000
0001
:
Forward running
0002
:
Reverse running
0003
:
Forward jog
0004
:
Reverse jog
0005
:
Coast to stop
0006
:
Deceleration to stop
0007
:
Fault reset