KE300A Inverter Parameter Description
159
Code
Name
Range
U0-14
Load speed
0
~
65535
U0-14 displays the speed of load. Refer to the description of P7-12 in user manual.
Code
Name
Range
U0-15
PID setting
0
~
65535
U0-16
PID feedback
0
~
65535
U0-15 displays the setting value of PID.
U0-16 displays the feedback value of PID.
Take the following formulas as follows:
The setting value of PID= the setting (percentage) of PID × PA-04
The feedback value of PID=the feedback (percentage) of PID × PA-04
Code
Name
Range
U0-17
PLC phase
0
~
F
U0-14 displays the current step when inverter is running in simple PLC mode.
The relationship between displayed value and current step is shown below.
Displayed value
Inverter is running at step X:
1
X:0
2
X:1
……
……
F
X:15
Code
Name
Range
U0-18
HDI input pulse fre.
0.00
~
100.0KHz
U0-18 displays the sampling frequency of High-speed-pulse input (HDI). The smallest unit is 0.01 KHz.
Code
Name
Range
U0-19
Feedback speed
-320.00
~
320.00Hz
-3200.0
~
3200.0Hz
U0-19 displays the actual output frequency of inverter:
When P0-22 is set to 1, the range is -3200.0 to 3200.0. (Unit: Hz)
When P0-22 is set to 2, the range is -320.00 to 320.00. (Unit: Hz)
Code
Name
Range
U0-20
Remain running time
0.0
~
6500.0min
U0-20 displays remain running time when inverter is running at timing running mode. (Refer to P8-42,