15.6.2012
Rev. 1.7
Operating instructions
10
5.
Keep the temperature increasing and decreasing buttons ("+" button and "–" but-
ton) simultaneously pressed until the display indicates 125°C and 1,5 bar. The
safety valve should now open and release steam. Release both temperature buttons.
NOTE! On kettles with jacket cooling C2 the test button on the right hand side of
the control pillar has to be kept pressed together with the + and the - buttons
1.
kettle on-off switch
2.
temperature adjustment buttons
1. Test button
If the safety valve does not open at the latest when the pressure gauge indicates
2
bar,
the
power must immediately be switched off using the green on-off switch. Contact qual-
ified service personnel. It is not allowed to use the unit before it has been checked.
The safety valve function must be checked at least four times per year. The manufacturer
is not responsible for damage caused by n eglecting the regular checking of the safety
valve.
Summary of Contents for Culino Combi 40S
Page 2: ......
Page 4: ...15 6 2012 Rev 1 7...
Page 50: ...15 6 2012 Rev 1 7 Troubleshooting 44...
Page 52: ...Installation drawing L00133 C3...
Page 53: ...Installation dimensions K02450 A3...
Page 54: ...Text L00134 B4...
Page 55: ...Steam supply recommendations 000030 A4...
Page 58: ......