15.6.2012
Rev. 1.7
Operating instructions
23
1. 3-way valve in cooling
position
6.
Open the water tap by turning the handle of the one-arm faucet for the cleaning
hose to the right and raise upwards.
The digital display indicates that the cooling has started.
Stopping the cooling
1.
Close the one-arm faucet by pressing the handle down.
2.
Remove the cleaning hose from the emptying valve.
3.
Turn the 3-way valve to the cooking position (upwards).
1. 3-way valve in cooking
position
4.
Let the extra water run out of the steam jacket through the emptying valve. Close
the emptying valve when the kettle is in an upright position and water stops flow-
ing out.
It takes a few minutes to let the extra water run out of the steam jacket. If you first want
to empty the kettle, close the emptying valve before tilting.
The kettle will not warm up properly, if cooling water is not completely drained from the
kettle jacket.