15.6.2012
Rev. 1.7
Installation
39
5.
Keep the temperature increasing and decreasing buttons ("+" button and "–" but-
ton) pressed at the same time until the display indicates 125°C and 1,5 bar. The
safety valve should now open and release steam. Release both temperature buttons
when the safety valve has opened.
NOTE! On kettles with jacket cooling C2 the test button on the right hand side of
the control pillar has to be kept pressed together with the + and the - buttons
1.
kettle on-off switch
2.
temperature adjustment buttons
1. Text button
If the safety valve does not open at the latest when the pressure gauge indicates
2
bar,
switch off the power using the green on-off switch and contact qualified service person-
nel. It is not allowed to use the unit before it has been checked.
The safety valve function must be checked at least four times per year. The manufacturer
will not take responsibility for damage caused by neglecting the regular checking of the
safety valve.