5.7 Testing the kettle
Do the following measurements and checks before taking the kettle into use.
5.7.1 Cooking mode
Before the kettle is switched on, the kettle jacket emptying valve must be closed.
Do the following:
•
Check that the kettle is in its upright position.
1. emptying valve cooking
position
•
If the kettle is equipped with a cooling option, also check that the outlet valve on
the safety device block is in cooking position (upwards).
1. 3-way valve in cooking
position
5.7.2 Checking the safety valve
Do the following measurements in order to check the safety valve:
1.
Do the checking when the kettle is empty.
2.
Switch the kettle on by turning the green kettle on-off switch to the ON position.
3.
Set the cooking temperature to 120°C by pressing the temperature increasing but-
ton marked with "+".
4.
When the display indicates 120°C, check that the pressure gauge shows 1,0 bar
pressure.