15.6.2012
Rev. 1.7
Installation
40
5.8 Testing the mixer
The basic conditions for the perfect function of the mixer are that the kettle is correctly
fixed to the floor according to the installation instructions. The kettle and the kettle pillars
must also be in a horizontal position.
5.8.1 Checking the functions
Switch on the mixer by pressing the start/stop button. Check the following functions:
•
the mixer is mixing at the lowest speed and only the lowest mixing speed indicator
light is illuminated
•
the mixer rotates clockwise
•
press the auto-reverse button
•
ensure the auto-reverse function, approx. 10 seconds clockwise and approx. 5 sec-
onds counter clockwise
•
try all rotating speeds by pressing the buttons to increase and decrease mixing
speed ("+" and "–" buttons)
•
try all the four pre-set mixing programs
1.
start/stop button
2.
auto-reverse button
3.
mixing speed indicator light
4.
mixing speed increasing button
5.
mixing speed decreasing button
6.
buttons of pre-set programs
7.
mixer on-off switch with indicator light
8.
emergency-stop button
You can find the speeds and the pre-set programs in the section describing the mixer.
5.8.2 Checking the safety equipment
The mixer must stop when the safety grid or the lid itself is removed. If a pre-set program
was on, the indicator light near the program button blinks. The operation will continue,
when the lid and safety grid are replaced and the same program button is pressed again.
The mixer must stop immediately when the emergency-stop switch is activated. The
switch is released by turning it clockwise until it jumps to its upper position. After this the
mixer can be restarted.
Summary of Contents for Culino Combi 40S
Page 2: ......
Page 4: ...15 6 2012 Rev 1 7...
Page 50: ...15 6 2012 Rev 1 7 Troubleshooting 44...
Page 52: ...Installation drawing L00133 C3...
Page 53: ...Installation dimensions K02450 A3...
Page 54: ...Text L00134 B4...
Page 55: ...Steam supply recommendations 000030 A4...
Page 58: ......