75
would be reflected (GPO).
Enabled the GPIO mode in order to use those I/O (located at the back of the Anubis), by doing so
two new entries, GPI and GPO will appear in the Triggers Settings.
GPI:
General-purpose Input
and the GPO:
General-purpose Output
GPI
Settings
Enter the GPI page in order to configure the GPI triggering function type and triggering modes.
Pulse: Action is executed when the (foot)switch moves from close to open state.
State: Action is executed when the (foot)switch moves to open state. Actions in Toggle mode
will reflect the state as follow: open = on, close = off
State Inverted: Action is executed when the (foot)switch moves to close state. Actions in Toggle
mode will reflect the state as follow: open = off, close = on
Create a new GPI action:
Determine what will be the action triggered
Created actions are by default enabled, but users can disable an Action at any time
Select to delete an action