47
to adjust themselves to the lowest latency that can be globally achieved.
* Ex-factory default mode
Clock
About the PTP Clock: The Precision Time Protocol (PTP) is a protocol used to synchronize
clocks throughout a computer network. Also known as IEEE 1588 or IEC 61588, it is a protocol
designed to synchronize real-time clocks in the nodes of a distributed system. RAVENNA is
based on and uses V2 of this IEEE standardized protocol. PTP Clocks allow for time resolution to
the Nanosecond.
PTP Master
If multiple AoIP devices are used in a network environment, Anubis will try to be elected as the
PTP Master priority when enabling this setting, using the Best Master Clock Algorithm (BMCA):
Note: Non-Merging devices might not consider Anubis as the PTP Master
PTP Status
Information on the Anubis PTP status. Save or Master indicator and Unlock, Locking and Lock
status.
ASIO Clock
Auto: The ASIO clock will be generated by the Anubis which will be PTP Master
On: The ASIO clock will always be generated by this Anubis whomever the Master
Off: The ASIO clock is never generated
Note: Set to Off only if you are sure that no Anubis will be PTP Master, or if you are configured for a
Unicast (point to point) workflow.
Interface Controls
Brightness Display
Adjust brightness of the TFT display using the Anubis rotary encoder to increase or decrease it.
Summary of Contents for Anubis Premium
Page 1: ...USER MANUAL V21 07 2020...
Page 2: ...2...
Page 22: ...22 ANUBIS ANALOGUE I O BLOCK DIAGRAM...
Page 67: ...67 Bass Management Signal flow...
Page 91: ...91 Downmix Table Monitor Channels Types vs Downmix formats available...
Page 120: ...120 Reset all the faders gain by double clicking on the fader itself...
Page 129: ...129 APPENDICES MIDI CONNECTOR Female 6 3 mm 1 4 TRS connector PIN OUT...
Page 132: ...132 MISCS Anubis PreAmps MIDI implementation...