63
Band Frequency (up to 12)
Adjusts the center frequency for the band.
Unit: Hz and kHz
Value Range: 20Hz / 20kHz
Default Value for first five bands: 31Hz / 125Hz / 500Hz / 2kHz / 8kHz
Step: 24 steps per octave
Gain
This knob sets the gain in dB of the selected bands between -24 dB and +24 dB.
This setting is only used for Peak and Shelving filter types.
Default Value: 0 dB
Step: 0.1 dB
Band Q-Factor (7)
Adjusts the frequency range affected by Gain and Frequency on the band when the Parametric
filter type is used. Q is only available for Peak Filter Type.
With a lower Q-Factor, a wider range of frequencies are affected, with a higher Q-Factor, a
narrower range of frequencies are affected.
Value Range: 1 to 100
Default Value: 10
Step: 24 steps logarithmically distributed.