OPERATION
23
NOTE: The following Table lists only the possible problem areas
and not specific error codes recorded by the PCM. Use a Digital
Diagnostic Terminal (DDT) or Computer Diagnostic System (CDS)
to extract specific problem codes from the PCM.
Problem
Horn
Monitor
Display
Guardian
Activated
Engine
Power
Reduced By
Battery range high
or low
3 Beeps‑1.5
Sec. Long
Yes
Yes
100% down
to 5%
Low Seawater
Pressure
Steady Horn
Yes
Yes
100% down
to 5%
Boost Valve Error Steady Horn
Yes
Yes
70%
Guardian
Envoked
Steady Horn
Yes
No
Low Oil Pressure Steady Horn
Yes
Yes
100% down
to 15%
Oil Temperature
Overheat.
5 beeps‑3 Sec.
Long
Yes
Yes
100% down
to 15%
Engine
Overspeed
Steady Horn
Yes
No
Rev limit with
no power loss
Reverse
Overspeed
3 beeps‑1.5
Sec. Long
Yes
No
Rev limit with
no power loss
Neutral
Overspeed
3 beeps‑1.5
Sec. Long
Yes
No
Rev limit with
no power loss
Coolant Overheat Steady Horn
Yes
Yes
100% down
to 15%
PCM Error
Steady Horn
Yes
Yes
Forced Idle
Coil Pack Failure 5 Beeps‑3 Sec.
Long
Yes
No
Fuel Injector
Failure
5 Beeps‑3 Sec.
Long
Yes
No
Fuel Pump Failure 5 Beeps‑3 Sec.
Long
Yes
Yes
70%
Idle Air Control
Failure
5 Beeps‑3 Sec.
Long
Yes
No
Transmission
Overtemp
3 Beeps‑1.5
Sec. Long
Yes
No
Summary of Contents for HP1200 SCi Dry Sump
Page 4: ...iv...
Page 8: ...viii...
Page 86: ...MAINTENANCE 78 Date Maintenance Performed Engine Hours...