MegaLife
ARV OUTDOOR UNIT
–
ARV 6 ALL DC INVERTER T1 50&60HZ Service Manual
112
6.2 Parameter setting by YK
– L
6.2.1 Enter the setting interface
①
Make sure the remote controller is
off
②
Press the
two white button
at the down side simultaneously
more than 10s
to enter the
address setting mode.
③
First, will display
“
1
”
,
“
1
”
,
④
the above number means : Series parameter number, from
1~15
⑤
the below number means
:
Meaning of parameter correspondence
For example:
Check “
6.1 Parameter Setting Items
” for number of parameters and corresponding
meaning.
“
1
”
,
“
1
”
, the indoor unit’s address is
1#
“
4
”
,
“
32
”
, the indoor unit’s type is
Wall - Mounted (L Type )