106
Operation
Xtrashift warning lamps
For warning lamps and information on the instrument
panel, see the Instruments and Programming Section in
this manual.
Engagement of Powershift ranges under load
The gearbox provides 3 Powershift ranges (underdrive,
direct drive and overdrive) that can be engaged under
load in forward gears.
For each engaged gear, 3 speeds are available: Underdrive
- Direct - Overdrive.
To select, turn the Powershift switch on the gearshift
lever: changes from one range to the next are automatic
and under load (Fig.4-15).
Turn the switch up to shift the range up: + sign.
Turn the switch down to shift the range down: -- sign.
The switch always returns to the centre position.
The Powershift switch can be set on any position with the
tractor moving, without depressing the clutch pedal or
the clutch pedal or the Declutch disengagement button.
To ensure that the ranges are shifted in the correct se-
quence, move the switch one range at a time in the 1,
2, 3 order.
IMPORTANT: To prevent excessive deceleration of
the tractor ALWAYS downshift one range at a time in
sequence 3, 2, 1.
On the digital instrument panel, the Powershift screen
displays the selected speed: see the Instruments and
Programming Section in this manual.
Reaction to control settings
The monitoring system automatically analyzes the condi-
tions in which the tractor is used and chooses reaction
times most suitable to any condition.
Summary of Contents for X60 Series
Page 39: ...39 Controls Cab 3 Section 3 Controls Cab...
Page 61: ...61 Instruments and Programming 4 Section 4 Instruments and Programming...
Page 90: ...90 Instruments and Programming This page has been left blank intentionally...
Page 91: ...91 Operation 5 Section 5 Operation...
Page 151: ...149 Tyres Wheels Ballasting 6 Section 6 Tyres Wheels Ballasting...
Page 168: ...166 Tyres Wheels Ballasting This page has been left blank intentionally...
Page 169: ...167 Maintenance 7 Section 7 Maintenance...
Page 229: ...Electrical system 227 8 Section 8 Electrical system...
Page 242: ...Electrical system 240 Page left intentionally blankf...
Page 256: ...Technical specifications 254 This page has been left blank intentionally...
Page 262: ...260 Alphabetical index...