53
ͲtĂƌŶŝŶŐ
C#&#" #"> # "
"##&
HORN
SHUT-
DOWN
CAUSE
REMEDY
YES
NO
Fuel level less than a 1/4
Fill up
NO
NO
The parking brake is on
Go foward or reverse to release
the breake
YES
NO
Hyd. oil level less than 2/3
Fill up and check eventual leaks
YES
YES
Low hyd. oil
Fill up and check eventual leaks
NO
NO
The alternator doesn’t load
the battery
Control the alternator and the
belt. Contact a Isuzu service.
NO
YES
The air filter is clogged
Change the elements
NO
YES
The hyd. oil filter is clog-
ged
Change the element
NO
NO
The preheating is on (Op-
tional)
Wait the light comes off and
proceed with the injection.
NO
YES
Low engine oil pressure
Check engine oil level and wire
connection.
NO
YES
Engine stop
Release the emergency red
switch and check eventual leds
on
NO
YES
Coolant temp. > 110° C
Clean the radiator, check the
coolant level, check eventual
leaks.
105
90
C
4/4
1/2
0
0