79
9.11 - SERVICE EVERY 50 HOURS
ATTENTION :
If the wiring show signs of short circuit contact
0F&211(/
SERVICE.
9.11.1 - ELECTICAL PLANT
This type of check is a visual check that must be carried out with the maximum expertise to
avoid short-circuits of the plant that would damage the machine.
$*"
- Fuses, if are corroded or rusty replace them with fuses of the same capacity.
- Battery, check the connection of the connection terminals to the battery and if they are rusty,
in this case remove the rust and cover them with appropriate grease: pay great attention in the
carrying out of this operation to not make contact the wire of chassis (black) with the wire of
electric power feed (red).
- Starter motor, check the cables.
- Alternator, check the cables.
9.11.2 - CHECK TIGHTENING DRIVE MOTOR SCREWS
Under normal operating circumstances, no routine
maintenance is required, except routine oil checks
and oil changes.
Its, however, required check on the tightening of
the mount screws.
Check all the screws with a torque wrench.
A =
Torque max 250 Nm.
B = Torque max 550-650 Nm.