88
To ensure proper lubrication and viscosity in the
hydraulic pumps, hydraulic oil must be replaced
at regular intervals.
#<= # " "
of oil previously removed. Do not mix diffe-
rent types of oils.
To change the oil, proceed as follows :
{" ^ +#
the ground to ensure the operations safely.
- Remove the protective covers from the bottom
and clean all parts thoroughly before procee-
ding with the opening of the oil drain plug (a).
{" " *+Z
- Remove the drain plug from the tank ( CH. 10
mm. ) Taking care to collect the used oil in a
large container (at least 100 L.)
- Tighten the cap at the end of operation .
- Introducing the new hydraulic oil depending
on the type used . ( Qty approximately 100 L. )
- Check the level on the visual inspection .
- As soon as he reached the proper oil level ,
start the engine and let it run for 10 seconds,
repeat process until you reach the boost pres-
sure (20-22 bar) on the pumps .
- Shut down the engine and recheck the oil
level
{ \ #
reaches the marking of the auction;
9.16 - SERVICE EVERY 2000 HOURS
9.16.1 - HYD. OIL REPLACEMENT
a
b
0F&RQQHO
will only guarantee that
WKH
product
LV
free from defects if Panolin HLP
Synthetic 46 Hydraulic Oil (when indicate
G
) is used in the hydraulic system. The use
RI
another hydraulic oil, or a mixture of the approved Panolin HLP and another oil may
severely affect the reliability of the RoboPower hydraulic system.
ATTENTION :
- McCONNEL ROBOPOWER -
Summary of Contents for ROBOPOWER 111300001
Page 3: ......
Page 27: ...23 3 2 6 DECAL DESCRIPTION EMERGENCY STOP McCONNEL ROBOPOWER...
Page 36: ...32 4 2 DIMENSIONS 4 2 1 UNIT 3550 mm 1620 mm 1900 mm McCONNEL ROBOPOWER...
Page 53: ......
Page 60: ...56 6 6 2 ELECTRICAL LOOM 6 6 3 HYDRAULIC SYSTEM McCONNEL ROBOPOWER...
Page 93: ...89 10 INSTRUCTIONS FOR EMERGENCY SITUATION 10 1 FIRE McCONNEL ROBOPOWER...
Page 94: ...90 11 NOTES McCONNEL ROBOPOWER...
Page 95: ...91 McCONNEL ROBOPOWER...