SUNROOF
09-15–3
09-15
SLIDING SUNROOF OPERATION
id091500100500
•
The glass panel opens/closes using tilting and sliding operations.
•
When the ignition switch is at the ON position, the sunroof operates by use of the sunroof switches.
•
When the ignition switch is in the ON position, the sunroof operates automatically using a one-touch operation
of the slide open/close and tilt up/down switches.
•
When the ignition switch is in the LOCK or ACC position, the slide-open and tilt-up switches operate
automatically, and the slide-close and tilt-down switches operate manually for 45 s or less until the front door
opens. (IG OFF timer function)
•
If any switch is operated during auto-operation, the sunroof stops.
•
If any malfunction is detected during sunroof operation, the fail-safe function operates to ensure safety.
End Of Sie
NG: SUNROOF UNIT
Item
Detection conditions
Fail-safe status
Cancel condition
Motor is stopped
Motor is operating
Obstruction detection
Obstruction load of 100
N {10.2 kgf·m,73.8
ft·lbf} or more
—
Reverse operation
•
Reverses to the full-
tilt position when
detected during tilt-
down operation.
•
Moves 200 mm
{7.87 in} in the open
direction (to fully
open position if
sunroof opens
within 200 mm {7.87
in}) when detected
during slide-close
operation.
Reverse operation
completed
Low voltage detection
Approx. 8 V or less
voltage detected
Operation prohibited
Operation continued
Voltage is within the
guaranteed operation
voltage
Over-voltage detection
Approx. 18 V or more
voltage detected
Operation prohibited
Operation stopped
→
Operation prohibited
Voltage is within the
guaranteed operation
voltage
Pulse sensor error
One side of the pulse
cannot be detected
—
Operation stopped
Switches to the starting
point, non-set
conditions
Sensor signal returned
to normal
Improper roof position
Pulse sensor output is
at the overflow value or
more, or at the
underflow value or less
(Only occurs when the
glass is moved forcibly
to the full-tilt position or
to the position
exceeding the full-open
position.)
Switches to the starting
point, non-set
conditions
—
Initialization of the roof
position completed
EEPROM error
Reading error of the
roof position data
preset in the EEPROM
when the operation is
started
Operation prohibited
—
EEPROM is read
normally
Microcomputer
overdrive
Watchdog timer clear
signal does not input
from the microcomputer
Operation prohibited
Operation stopped
→
Operation prohibited
Normal operation is
started after the
microcomputer power-
on reset
Element breakage
affecting closing
operation
—
Operation prohibited
Operation stopped
→
Operation prohibited
Does not recover from
operation prohibition
3423-1U-06H(09-15).fm 3 ページ 2006年11月21日 火曜日 午後5時42分
Summary of Contents for 2007 CX-9
Page 14: ......
Page 36: ......
Page 56: ......
Page 66: ......
Page 72: ......
Page 80: ......
Page 96: ......
Page 100: ......
Page 102: ......
Page 116: ......
Page 126: ......
Page 134: ......
Page 146: ......
Page 148: ......
Page 154: ......
Page 156: ......
Page 180: ......
Page 220: ......
Page 236: ......
Page 280: ......
Page 288: ......
Page 296: ......
Page 302: ......
Page 344: ......
Page 352: ......
Page 372: ......
Page 376: ......
Page 380: ......
Page 408: ......
Page 464: ......
Page 572: ......
Page 592: ......
Page 614: ......