E00: Error message
>
00 will contain a 2 digit decimal error code.
5.6 Command argument values
Command arguments are shown in the Help command output surrounded by square brackets '[ARG]' or
parenthesis '(ARG)'. Square brackets indicate an optional argument and parenthesis indicate a required
argument. Any optional argument specified requires that all prior optional arguments are also specified.
Argument
Valid Range
Meaning
DEST
1-N
Destination number (N = Count of destinations)
SRC
1-N or 0
Source number (N = Count of sources), 0 acts as
mute (if supported).
LEVEL
1-N
Level number (N = Count of system levels)
PRESET
0-9
Preset number (preset 0 is special Startup preset)
IP
D.D.D.D
IP address string argument, specified as 4 decimal
digits from 0 to 255 separated by periods.
NETMASK
D.D.D.D
Network mask string argument, specified as 4
decimal digits from 0 to 255. Must be a valid
IPv4 netmask.
JSON
string
JSON formatted string, the structure of which
depends on the command. The JSON string
should be quoted in single quote characters when
specifying a JSON value in a command.
LABEL
string
A string label argument, max of 8 characters.
PROFILE
1-N
Profile index number (N = Count of
MtxProfiles
)
STR
string
A generic string argument (max length depends
on the command).
5.7 Error codes
This following table shows possible error codes which may be returned in response to commands.
Error #
Message
Description
E01
Token too long
A command name or string argument was too long.
E02
Invalid command
Invalid command name.
E03
Invalid argument
One or more invalid argument values.
Page 41 of 75
©
2013 Matrix Switch Corporation
www.matrix-switch.tv