![Manning YB8 Operating And Instruction Manual Download Page 88](http://html1.mh-extra.com/html/manning/yb8/yb8_operating-and-instruction-manual_701729088.webp)
PROGRAMMING SECTION
MODEL YB8
April 1999/Manning Environmental Inc.
3DJH%
ACTIVE PERIOD?
__ __ : __ __
04:30:02
Enter a time (HH:MM format). This is the time window in which
bottle groups are active. It applies to all bottle groups. Make sure it
is long enough to allow the sampler to collect the number of samples
required.
# OF BOTTLE GROUPS?
__ __ __ __
04:30:02
Enter a 2-digit number (must be an integer). This is the number of
bottle groups to be created from the number of bottles set in *99.
PUSH START/OPTIONS
04:30:02
If no add-on options are desired, press <START> to begin the
program.
DELAY START TIME
__ __:__ __
04:30:02
This display shows the time remaining on the Delay Start.
FLOW MODE (*13)
__ __ __ __
04:30:02
Once the Delay Start ends, the sampler will immediately begin
reading the analog signal and begin counting down the Time
Override.
Summary of Contents for YB8