Removal
1.
Cage the spring brake.
2.
Tag, remove, and cap the air lines to the brake air
chamber.
3.
Remove the pin(s) connecting the clevis to the slack
adjuster.
4.
Mark the position of the clevis on push rod so that the
clevis can be reinstalled in the same position.
5.
Unbolt the air brake chamber from the mounting bracket
and remove the air brake chamber.
Installation
Refer to (Figure 8-48).
1.
Bolt the air brake chamber to the mounting bracket.
2.
Install the pin through the clevis and slack adjuster.
3.
Check brake adjustment.
4.
Uncage the spring brake.
Disassembly
Refer to (Figure 8-49).
.
1.
Remove the clamp securing the service brake chamber
to the spring brake chamber.
2.
Separate the lower cover from the spring brake
chamber.
3.
If the push rod or spring needs to be removed, mark the
position of the clevis on the push rod. Remove the clevis
and jam nut.
4.
Remove the push rod.
Assembly
Refer to (Figure 8-50).
1.
Insert the push rod through the spring and cover.
2.
Screw on the jam nut and clevis as per removal marks.
3.
Position the diaphragm over the push rod.
4.
Push the lower cover assembly into the spring brake
chamber and secure with the clamp.
WARNING
Death or Injury Could Occur!
Cage the spring brake before removal of air brake
chamber.
Brake Air
Chamber
Differential
Drive Shaft
Torque Rod
Axle #3
Jack Beam
Mounting
Bracket
7093-5b
FIGURE 8-48
Mounting Bolt
Push Rod
Clamp
Service
Brake
Chamber
Air Ports
Spring Brake
Chamber
Caging Bolt
Caging
Bolt
Stowage
7093-5c
FIGURE 8-49
Fo
r
Reference
Only