SUPERSTRUCTURE MAINTENANCE
TMS9000-2 SERVICE MANUAL
5-6
Published 01-14-2021 Control # 707-01
Maintenance Plan M 1: Monthly/After 100
Operating Hours/Approximately 2,000 km
(1240 mi)
Maintenance Plan M 3: Every 3 Months/After
300 Operating Hours/
5 000 - 6 000 km (3,100 - 3,730 mi)
Maintenance Plan M 6: Every 6 Months/After
500 Operating Hours/10 000 - 12 500 km
(6,210 - 7,770 mi)
Maintenance Work on the SUPERSTRUCTURE:
Monthly/After 100 Operating Hours
Hook Blocks
Hydraulic System of the Superstructure
• Bleed the telescoping cylinders, page 4-44
• Bleed the lift cylinder
Other Maintenance Work
• Check for correct operation of the auxiliary heater (additional equipment)
• Lubricate cabin door track rollers.
• Lubricate the connecting and socket pins.
• Lubricate the spring latch.
Maintenance Work on the SUPERSTRUCTURE:
Every 3 Months/After 300 Operating Hours
Ball Swing Connection
• Check tightness of retaining bolts;
Main Boom
• Lubricate locking pins
• Lubricate telescopic slide faces, page 9-23
Maintenance Work on the SUPERSTRUCTURE:
Every 6 Months/After 500 Operating Hours
Swing Gears
• Lubricate the swing gear pinions, page 9-18
Superstructure Air Conditioning System (Additional Equipment)
• Check hoses
RCL
• Maintain the slip ring assembly in the cable drums; page 4-53