![Manitowoc Grove TMS9000-2 Series Service Manual Download Page 132](http://html.mh-extra.com/html/manitowoc/grove-tms9000-2-series/grove-tms9000-2-series_service-manual_701234132.webp)
3-12
Published 01-14-2021 Control # 707-01
ELECTRICAL SYSTEM
TMS9000-2 SERVICE MANUAL
Because the pins and sockets are crimped to the wires, it is
not possible to remove them. Using the proper extraction
tool, remove the pin(s) or socket(s) from the plug or
receptacle. Cut the wire as close to the pin or socket as
possible. After cutting the pin or socket off, the wire will most
likely be too short. Using a wire that is too short will allow
pressure to be applied to the pin or socket and wire where
they are crimped when the pin or socket is inserted in the
plug or receptacle. Add a short length of the same size wire
to the short wire by crimp splice or solder. Use heat
shrinkable tubing or other suitable material to insulate the
splice.
Di-Electrical Grease Application
Since March 2018 Manitowoc Cranes has been using Di-
Electric Grease on all electrical connectors. All of the below
electrical connection received Di-Electric Grease:
•
All Deutsch Connectors.
•
All Valve Solenoid connections on Hydraulic valves and
Transmissions.
•
All Harness Connections.
•
CCS Module Connections.
When servicing electrical connections on Cranes, you
should reapply Di-Electric Grease per the instructions below:
•
Check connection for moisture before application of the
grease.
•
If moisture is found, please clean/replace connector
accordingly.
•
Apply material immediately prior to connection.
•
Make sure that there is coverage to all terminal sockets.
Procedure
Required Material: Manitowoc P/N 90045471 - Di-Electric
Grease.
1.
Screw the tip/trigger assembly onto the can, if
necessary.
2.
Squeeze the trigger to dispense the material onto the
female (socket) contact.as shown in (Figure 3-13).
3.
Use a clean towel (or clean glove) to remove any excess
material from the surface of the connector, and wipe
material into the terminal sockets as shown in
(Figure 3-14)
4.
Make sure that each socket has material. The towel with
excess material can be used to fill empty terminal
sockets as shown in (Figure 3-15).
5.
Make sure that grease is also applied to the entire
surface of the rubber seal as shown in (Figure 3-16).
4, 6, 8, 10 gauge wire
HDT 04-08
9999100842
Description
Deutsch Part Number
Grove Part Number
6862-41
FIGURE 3-13
Grease Application
6862-42
FIGURE 3-14
Clean off Excess Material
6862-43
FIGURE 3-15
Make sure Coverage in each Socket
Fo
r
Reference
Only