FIGURE 4-35
Damage
Description
Cause
Replacement
Wire Breakage
Wire Breakage
Clusters (2),
Strand Breakage
Individual wires are
broken; the broken
ends of the wires are
protruding from the
rope.
General wear caused by
aging of the rope
or
subsequent damage
resulting from damage to
the rope.
Replace hoist rope
at the latest
when the maximum permissible
number of wire strand fractures
according to the table are visible
externally.
Replace hoist rope
immediately
if wire
breakage clusters or strand breakage
occur.
The frequency of wire breakage
increases with rope age. For reasons of
safety, it is advisable to replace the
hoist rope while the number of broken
wires is still low.
Effect of Heat
Tarnishing color is
visible externally on
the rope.
Rope has been subjected
to strong heat.
Replace hoist rope
immediately
.
Fo
r
Reference
Only