![Manitowoc Grove TMS9000-2 Series Service Manual Download Page 136](http://html.mh-extra.com/html/manitowoc/grove-tms9000-2-series/grove-tms9000-2-series_service-manual_701234136.webp)
3-16
Published 01-14-2021 Control # 707-01
ELECTRICAL SYSTEM
TMS9000-2 SERVICE MANUAL
Installation
1.
Place the starter on its mounting pad. Secure the starter
with the bolts.
2.
Connect the electrical leads to the terminals as tagged
during removal.
3.
Connect the batteries.
4.
Install the ECM power fuse.
5.
Turn the battery disconnect switch to the ON position.
6.
Close the engine compartment.
Check
1.
Try to start the engine. Verify the starter starts the
engine.
2.
Start engine again, and listen for starter noises. Verify
there is no abnormal noise indicating the starter’s gear is
meshing improperly with the flywheel, that the starter’s
gear hasn’t disengaged from the flywheel after the
ignition switch is in the ignition (run) position, or some
other problem. Install starter properly as needed.
Battery Replacement
Removal
1.
Make sure that the key switch has been in the OFF
position for 2 minutes.
2.
Turn the battery disconnect switch(1, Figure 3-24) to the
OFF position.
3.
Remove the ECM power fuse.
4.
Remove the negative battery cables (4, Figure 3-24).
5.
Remove the positive battery cables (2).
6.
Remove the nuts and washers from the bracket hold
down rods (2). Remove the hold down brackets.
7.
Remove the batteries.
CAUTION
To avoid possible engine fault codes and undesirable
operation, ensure the key switch has been off 2
minutes before disconnecting batteries.
Disconnect batteries if machine will be inactive for over
24 hours.
FIGURE 3-23
9285a
Fo
r
Reference
Only