2.5.
SAFETY FEATURES
2.5.1.
POWER FAILURE DATA RECOVERY
During alignment, if the power goes off & resumes, the system has the facility
to resume the previous job without redoing the entire alignment again.
When the power goes off, system will operate in UPS mode. Press Ctrl+S to
save the job and shut down the PC. After the power resumes, the system will
prompt the following message “
Resume previous Job ?
”. If the previous job
need to be continued, press
YES
button to continue with the old job or else,
press
NO
to start a new job.
2.5.2.
CONTROL FUSES
Control fuses are incorporated to protect the electronic components against
high current. The Fuse holders are mounted on the Interface box (F1 & F2)
which can be easily accessed from outside for replacing the blown fuse.
Always replace the Control fuse with same type and rating of CE marked
Fuse.
2.5.3.
HIGH VOLTAGE PROTECTION
Power to the equipment should be routed through Un-interrupted Power
Supply (UPS) with Automatic Voltage Regulator (AVR) function. This will
maintain output voltage within limit to avoid Electronic boards & components
against failure due to high Voltage.