![Mahindra Thar CRDe Repair Manual Download Page 99](http://html1.mh-extra.com/html/mahindra/thar-crde/thar-crde_repair-manual_695011099.webp)
Repair Manual MAN-00
190
THAR
CRDe
BS-IV
MAY
2012
/Rev 1
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present
document, are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of
Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution© 2012 Mahindra & Mahindra Ltd.
Technical Specifications
Parameter
Description/ Value
Radiator capacity
2.15 liters
Cooling system capacity
9.3 liters
Coolant to be added after draining/flushing
2.79 liters
Viscous Fan Drive
- fan starts at ( For reference only)
75
°
C of air temperature at Sensor
Input speed – 3600 rpm
Viscous Fan Drive
- fan stops at ( For reference Only)
35
°
C of air temperature at Sensor
Input speed – 1300 rpm
Input speed of Fan pulley
1.30 x Engine speed.
Fan Belt tension
New installation –165 ± 2 Hz
Stabilized –134 Hz Min
Fan Belt tension - Gates make
New installation –170 ± 5 Hz
Stabilized –140 Hz Min
Cooling system :
Liquid cooling system
Nature of coolant/ liquid and capacity
Ethylene Glycol based coolent & water in ratio
30:70, Capacity 4.2 litr. (Only engine).
Characteristics of Circulating pump or make(s) &
type(s)
Autolec Industries, Chennai,
Centrifugal Pump
Drive ratio
1.3
Thermostat type and setting
Wax type, starts open at 82
0
C and fully open at 96
0
C
Radiator :
Type(s)
Cross flow, Aluminium radiator.
Relief valve pressure setting
0.9 bar
Nos. of blades
11
Materials of blades (metal / Plastic)
Plastic
Types(s) (Fixed/Viscous/Eletrical driven)
Viscous
Fan drive system
Belt drive
Drive ratio
1.3
Fan cowl
Provided.
Fan diameter (mm)
400
Max. speed of fan (in rev/min)
5500 +/-100 rpm
Radiator core open area, cm
2
2200
Max temp. at engine outlet
106 °C
Max. outlet temperature of the intercooled- air
(Location of measurement to be specified).
75 °C measured at 75 mm from Intercooler outlet
Max. exhaust temperature
650 °C at 150mm from Turbocharger outlet flange.
(in case of diesel engines, at the point in the
exhaust pipe(s) adjacent in outlet flange(s) of
exhaust manifolds),specify the distance from the
oulet flange.
Torque Specification
Location
Torque in Nm
Viscous Fan clutch nut
45 ± 5 Nm (33 ± 4 lbf-ft)
Page 97