Care of the System
Following are the regular maintenance activities to be carried in Cooling System -
COOLANT LEVEL & LEAK – INSPECT
Coolant
–
MAXIMILE Ultra Cool (Pre-mixed)
Capacity – 8.0
Lit.
---
----
-----
---
----
-----
HIGH
LOW
COOLANT LEVEL - INSPECT
Refer illustrations shown.
•
Check the coolant level when the engine is cold.
•
Check the coolant level in the recovery tank [2] – it should be between HIGH and LOW
marks. If below MIN, top it up with Maximile Coolant.
•
Check the coolant level in the radiator [1] and top up if found less. Use MAXIMILE Ultra
Coolant directly from the container to top up. Maximile Ultra Coolant is pre-mixed and
hence do not dilute it with water.
•
Check for evidence of leakage at Water pump hose, thermostat hose, and Oil cooler
hose [3]. Radiator top and bottom hoses and HVAC heater hoses.
•
Never remove the radiator cap when the engine is hot.
•
Never mix MAXIMILE Ultra coolant with water. It is pre-mixed.
•
Replace coolant at every 60,000kms.
•
If the activity is done on a 2 post lift, ensure that the LSPV spring is disconnected before
lifting the vehicle. After lowering, re-connect the LSPV spring and ensure that the
setting height is correct.
1
2
3
---
----
-----
---
----
-----
HIGH
LOW
Page 80