PC Program Operation
Eurosystem / Profi-LON
D1 E101BA1-GB09
4.23
4.4.1 Brake
Test
Although the following screens only show values recorded for the front axle, the description for
the re-display of brake tests applies also to the parking brake and the rear axle.
1 Select <1>. The brake test selection menu
appears.
2 Select the brake values to be re-displayed:
<1> front axle
<2> parking brake
<3> rear axle
<4> final evaluation.
The display of the brake force values
appears which are part of the automatic
testing procedure. Measurement value
which are outside the approved limit values
are shown in red.
3 Select among <FA>, <PB> or <RA>, to
switch between the displays for front, rear
or parking brake. The keys/boxes <F2> and
<F3> have the same function.
The box „Testing:“ shows which brake the
measurement values apply to.
4 Use <ESC> to exit the screen and return to
the selection display.
5 Use the box Print or function key <F12> to
print out the measurement values.
6 Use the <
È
> key to page forward to the
next key which gives more information
about the measurement values.
7 Use the <
Ç
> key to page back to the
previous screen.
8 Use <F4> BF-Graphic and <F5> Pedal
Graphic to page to the appropriate graphic
(screens and explanations next page).
Summary of Contents for SA 2 Euro
Page 19: ...Eurosystem Profi LON Safety 2 4 D1 E101BA1 GB09...
Page 39: ...Eurosystem Profi LON Profi LON Operation 3 20 D1 E101BA1 GB09...
Page 119: ...Eurosystem Profi LON Maintenance Troubleshooting 5 8 D1 E101BA1 GB09...
Page 128: ...Appendix Eurosystem Profi LON D1 E101BA1 GB09 6 9 6 2 Short Instructions...
Page 129: ...Eurosystem Profi LON Appendix 6 10 D1 E101BA1 GB09...
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......