Eurosystem / Profi-LON
Maintenance / Troubleshooting
5.6
D1 E101BA1-GB09
5.5 Troubleshooting
5.5.1
Shock Absorber Tester / Suspension Tester
Description
Cause
Remedy
Shock absorber tester will not start up.
Shock absorber tester occupied when being
started.
Turn off main switch.
Remove vehicle from test stand.
Turn on main switch again.
5.5.2
General / Brake Tester
Description
Cause
Remedy
READY lamp does not light up after test stand has been switched on.
No power supply
Restore power supply.
Fuse defective.
Contact service.
Lamp defective
Contact service.
Roller set will not start up. Error code 32 / 33 / 34.
Protective motor switches off and/or
defective.
Contact service.
One roller set side starts up and switches off again.
RPM signal missing, proximity switch
defective, protective motor switch on one
side off.
Switch on protective motor switch.
Contact service.
Measurement values not correct.
Zero point / amplification not correct.
Contact service to recalibrate test stand.
No screen display.
Display switched off.
Switch on display.
Cable connection OK?
Check cable.
Summary of Contents for SA 2 Euro
Page 19: ...Eurosystem Profi LON Safety 2 4 D1 E101BA1 GB09...
Page 39: ...Eurosystem Profi LON Profi LON Operation 3 20 D1 E101BA1 GB09...
Page 119: ...Eurosystem Profi LON Maintenance Troubleshooting 5 8 D1 E101BA1 GB09...
Page 128: ...Appendix Eurosystem Profi LON D1 E101BA1 GB09 6 9 6 2 Short Instructions...
Page 129: ...Eurosystem Profi LON Appendix 6 10 D1 E101BA1 GB09...
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......