Eurosystem / Profi-LON
Appendix
6.8
D1 E101BA1-GB09
6.1 System
Variables
No. Description
Default
Unit Comments
190 Turning Plate: No. of Impulses per rotation
1000
Imp./U
191 Turning Plate: Timeout after occupied
10
s
192 Turning Plate: Limit value for angle Difference
0.02
Grad (
°
)
193 Noise level: Calibration factor
5781
Quest 2400 = 5781
194 Noise level: Offset
49.4
Quest
2400
195 Noise level: Limit value orange
90
196 Noise level: Limit value red
90
197 ES_IN limit value storage after completion
only if ES_IN ES_OUT active
1
0 = no
1 = yes
198 Motorcycle test
0
0 = Manual start
1 = Automatic
199 4 gas test ( channel 1 ) request with F11 key
0
0 = automatic
1 = active
200
Test Equipment-Adminstration
pre-warning days till next calibration
10
201 Singapore Special mode
Minc with switching
1
0 = no
1 = yes
202 Side-slip tester- only test with front axle
0
0
=
no
1 = yes
203 to
204 not used
--
--
205 Brake tester: Automatic Oval test
1
0 = no
1 = yes
206 Brake tester: Autom. Oval test with parking brake
0
0 = no
1 = yes
207 not used
--
--
208 Brake tester: dynamic weight only when variable 209 = 1
0
0 = no
1 = yes
209 Brake tester: own scale
0
0 = no
1 = yes
210
to
219
to 219 not used
--
--
Summary of Contents for SA 2 Euro
Page 19: ...Eurosystem Profi LON Safety 2 4 D1 E101BA1 GB09...
Page 39: ...Eurosystem Profi LON Profi LON Operation 3 20 D1 E101BA1 GB09...
Page 119: ...Eurosystem Profi LON Maintenance Troubleshooting 5 8 D1 E101BA1 GB09...
Page 128: ...Appendix Eurosystem Profi LON D1 E101BA1 GB09 6 9 6 2 Short Instructions...
Page 129: ...Eurosystem Profi LON Appendix 6 10 D1 E101BA1 GB09...
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......