Profi-LON Operation
Eurosystem / Profi-LON
D1 E101BA1-GB09
3.15
3.6.2
Manual Operation with Remote Control
The single wheel mode is activated by pressing the Motor-On key of the side in question when
the vehicle is already on the test stand.
Remote Control
IFB3
Motor left
Motor right
b
= Motor off
c
= Motor on
Once test lane is ready (section 3.2.1) proceed as follows.
1 Activate manual operation
Press any Motor-Off key of remote control
→
Left pointer moves from zero position of side-slip tester
(if present) to zero position of shock absorber tester.
Lamps of analog display blink briefly for confirmation.
2 Noise
investigation
Drive onto test plates, then press Motor-On key of desired side.
→
Selected test plate starts vibrating.
Never exit the shock absorber test plates when they are vibrating. This can result in
equipment damage.
3 End noise investigation
Switch off the vibrating test plate again with the appropriate Motor-Off-key, then exit the test
stand.
4 Return to automatic mode
System automatically changes back to automatic mode.
→
ON lamp blinks once..