Maguire Products, Inc.
Rev. December 18, 2019
– ULTRA-1000 Touchscreen
36
ULTRA By Maguire
- Ultra Low Energy Dryer
Throughput Alarm -
If the Throughput alarm is enabled, the alarm
will sound if the material in the Retention Hopper is used faster than
the dryer can produce dried material. (Material level reaches RTL
parameter before the Vacuum Time Setting expires VTS parameter)
ON:
If the Throughput alarm is enabled, the alarm will
sound when this alarm is triggered.
OFF:
Disables the Throughput alarm
Vacuum Chamber Dump Alarm -
If the Vacuum Chamber Dump
alarm is enabled, the dispensing of material from the vacuum
chamber into the retention hopper is monitored using the CDR
(Chamber Dump Retries) parameter. CDR’s default settings of
05003 requires that at least 50% of the material that is in the
vacuum chamber be detected in the retention hopper after the
dispense.
If it’s under 50% the dispense will retry 3 times before
triggering the alarm. Retries will continue indefinitely until 50% is
satisfied.
ON:
If the Vacuum Chamber Dump alarm is enabled,
the alarm will sound when this alarm is triggered.
OFF:
Disables both the vacuum chamber dump alarm
and vacuum chamber Dump retries.
Print Alarm Log -
Prints the Alarm Log. See page 74.
Clear Alarm Log -
Clears the Alarm Log. See page 74.
Auto-Start Setup
Auto-Starts the Dryer at a specified Time and Day(s). Can be set to
Auto-Start the Dryer at one time only or on a repeated schedule.
Must be turned ON in Display Setup (see below).
Auto-Stop Setup
Auto-Stop the Dryer at a specified Time and Day(s). Can be set to
Auto-Stop the Dryer at one time only or on a repeated schedule.
Must be turned ON in Display Setup (see below).
Convey Setup
Convey Setup - Material Convey Options - Optional -
Uses
dedicated outputs on the I/O board that may be used to control
customer supplied Loader(s).
See the I/O Board Wiring Diagram at the end of this manual.
•
Loader 1 -
Off / Auto - Stops loader that supplies the heating
hopper for shutdown sequence.
•
Loader 2 -
Off / Auto - When material is ready, loader will
convey material away from dryer retention hopper. When
enabled, select Throughput or Weight.
•
Reset Totalizer -
Resets Weighed totals to zero. Totals are
the amount of material that has been conveyed away from
the dryer since the Totalizer has been reset.