Maguire Products, Inc.
Rev. December 18, 2019
– ULTRA-1000 Touchscreen
55
ULTRA By Maguire
- Ultra Low Energy Dryer
VSO -Vacuum Shutdown Offset
format:
xxxxx (seconds)
function(s):
Amount of time before the vacuum time (VTS) expires that vacuum pressure
equalization begins. This is to compensate for equalization time.
LVT -Vacuum Shutdown Offset
format:
xxxxx (seconds)
function(s):
Amount of time the vacuum generator will run before a LOW VACUUM condition
check is made. See LOW VACUUM alarm in Alarms section.
NVT - No Vacuum Timeout
format:
xxyyy (counts / seconds)
function(s):
xx:
Number of vacuum gate recycle attempts that will be made in an attempt to
clear a vacuum fault before a NO VACUUM alarm is triggered.
yyy:
Amount of time the vacuum generator will run before a NO VACUUM condition
check is made. See NO VACUUM alarm in Alarms section.
VPT -Vacuum Purge Timer
format:
xxxxx (seconds)
function(s):
Additional time the vacuum chamber purge/equalization valve will remain open after the
vacuum chamber reaches equalization pressure. This is to ensure that the vacuum
chamber is not left under a partial vacuum state at the end of a vacuum cycle.
VPI - Vessel Purge Interval
format:
xxyyy (seconds / seconds)
function(s):
xx:
Duration of a vacuum chamber purge cycle.
yyy:
Interval between vacuum chamber purge cycles.
ATM - Atmospheric Pressure
format:
xxxxx (mm Hg absolute)
function(s):
The measured atmospheric pressure. This parameter is automatically updated once per
cycle.