Maguire Products, Inc.
Rev. December 18, 2019
– ULTRA-1000 Touchscreen
15
ULTRA By Maguire
- Ultra Low Energy Dryer
Engaging the Load Cells
The Load cells are disengaged for shipping and must be engaged for
proper operation of the ULTRA-1000 Dryer. There are two sets of load
cells: the Vacuum Chamber load cell and the Retention Hopper load cell
pair.
Vacuum Chamber Load Cell
The Vacuum Chamber load cell is
located between the Vacuum
Chamber and the Vacuum Chamber
Assembly (B).
To engage the load cell, turn the load
cell lifting bolt down until it engages
the load cell located below. Continue
turning until the Vacuum Chamber
hanger is lifted 1/4 inch (6mm) off of
the sliding rail.
Lifting bolt, 1/4" (6mm) gap
Engage load cell
Retention Hopper Load Cell Pair
The Retention Hopper load cell pair is located
in front of and below the Retention Hopper.
To engage the Retention Hopper load cell pair,
remove the packaging straps from the
Retention Hopper Lifting Lever. Lower the
Retention hopper onto the load cell by pressing
the lever back and down. This will engage the
Retention Hopper lower frame onto the load
cell pair.
When the Retention Hopper Lifting Lever is in
its upright position, the lever's cams lift the
weigh off of the load cell pair and allow the
Retention Hopper to be pulled out for servicing
and cleaning purposes.